Metal tube float flow meter adopts variable area measuring principle to measure liquid and gas of multiple directions.
Chat NowMetal Tube Float Flow Meter Metal tube float flow meter adopts variable area measuring principle to measure liquid and gas of multiple directions. It is widely applied in industries such as petro,chemical,poer supply,food,pharmcy and water treatment,etc. |
INDICATOR INDTODUCTION
M1 Indicator
1.Introduced a pair of coupled magnet to realize flow indicating and transmission of electric signal.
2.Introduced the newest ESK signal transmitter with 4~20mA output.
3.Compatible with HART agreement.
4.Equipped with upper and lower limit alarming switch.
5.Intrinsic safety structure design with ExibIICT5 and EXiaIICT1-T4 explosion-proof mark.
M2 Indicator
1.Through cam board transmitting non-linear magnetic float to be linear current value and indicated by indicator needle on the dail.
2.Equipped with 4~20mA output angular rotation transmitter of KSW1.
M6 Indicator
1.Adopts magnetic snesor to response drift of magnetic float. Output 4~20mA amd digital display without magnetic lag.
2.Digital display instantaneous flow and accumulative flow.
3.Compatible with HART agreement.
4.Explosion supression standard with ExdIICT4-T6.
Main Parameter
Measuring Range | water(20℃):.5~180,000L/h air(20℃,101325 Pa):0.07~1800m3/h |
Range Ratio | DN15~100: 10:1 DN125~150: 5:1 |
Accuracy | 2.5 / 1.5 |
Max.Operation Pressure | DN15~50: 4.0 MPa DN80~150: 1.6 MPa |
Jacket Pressure | 1.6 MPa |
Medium Temperature | -80~+200℃ 0~80℃(non-corrosive model) |
Environment Temperature | -25~+120℃ -20~+70℃(electric remote transmission model) -20~+60℃(LCD display model) |
Medium Viscosity | DN15≤5mPa.s DN(25~150)≤250mPa.s |
Connection Type | flange, can OEM according to the specific requirement |
Protection | IP65 |
Electric Remote Transmission | 24(1±10%)VDC, 4~20mADC or 2-wire(HART for option),RS485 |
Linear | 1% |
Load Resistance | ≤500Ω(24VDC) |
Temperature Effection | <±0.05%F.S/℃ |
Power Consumption | <1W |
Cable | RVVP3×28/0.15 |
Limit Alarm | RVVP3×2Voltage:24(1±10%)VDC power consumption:<1W operation temperature:-25~+65℃ max.load current: 50mA8/0.15 |
Instrinsic Explosion-proof | EXibIICT5 / ExiaIICT1-T4 |
Explosion Suppression | ExdIICT4-T6 |