1 Description
The flowmeter operates on the float measuring principle. The measuring section consists of a metal cone in which a float can move freely up and down. The medium flows through the flowmeter from bottom to top.
The variable area flowmeters are suitable for measuring gases, vapors and liquids with specialty of solid, steady and reliable. CMDKW series are instructions type, and LZDW series are with electronic display and electronic signal output(4~20mA, compatible HART Protocol). The flowmeters are available as inlet or outlet pressure regulator. It also select install 1 or 2 limit switches.
|
|
|
|
CMDKW—F12—type (horizontal conntection) | CMDKW—F10 type (vertical conntection) | CMDKW—F12/K1 type (horizontal conntection with limit switches) | LZDW—F12 type (horizontal conntection) |
2 Description Code
The description code consists of the following elements*:
CMDK(D)W — □ / □ / □
① ② ③
① F10 without valve and vertical connection
F12 with valve and horizontal connection
② RR1 Material 304
RL Material 316L
③ K1 One upper limit switch
K2 One lower limit switch
K12 Two limit switches
* Positions which are not needed are omitted (no blank positions).
3 Technical data
3.1 Measuring ranges:Water(20℃)0.3~100 L/h
Air(20℃ 101325Pa)5~3400 L/h
3.2 Measuring span: 10∶1
3.3 Accuracy: CMDKW Series: 4.0; LZDW Series: 2.5
3.4 Maximum Pressure: 2.5 or 6.4MPa
3.5 Medium Temperature: —80~+150 ℃
3.6 Ambient Temperature: —25~+65 ℃
3.7 Connection Type: 1/4″NPTF
3.8 Limit Switch: 1 or 2
3.9 Electronic signal type:
Power supply: 24(1±10%)V DC
Output signal: 4~20mA DC, compatible HART Protocol
3.10 Protection category: IP65
Previous: Electromagnetic Flow meter specification
Next: Selecting The Right Rotameter Part 6——Metal Tube Float Flow Meter
Related Industry Knowledge
- Bi-thermometer brief introduction
- How to choose suitable tubine flowm...
- Turbine Flow meter Dimension
- Precious metal thermocouple
- High temperature metal sheathed tem...
- Optical-ectricity level switch
- Selecting The Right Thermometer Par...
- Intelligent radar level meter
- Turbine flow meter Selection of con...
- Electromagnetic Flow meter specifi...
- Selecting The Right Thermometer Par...
- Ultrasonic level sensor
- Metal tube Float Variable Area Rota...
- Selecting The Right Thermometer Par...
- Selecting The Right Rotameter Part ...
- Electromagnetic Flow meter technic...
- Electromagnetic Flow meter Working...
- Selecting The Right Glass Rotameter...
- Selecting The Right Glass Rotameter...
- Magnetic column (magnetic column) l...